€2.47 (Sin IVA)
Emergency Exit Sign Press Bar to Open COFAN
Emergency Exit Sign Press Bar to Open COFAN
Luminescent sign, available in various sizes
2,68 € (No tax)
€2.68 (Sin IVA)
Emergency Exit Sign Press Bar to Open COFAN text and pictogram. It is a high quality and easy installation emergency sign. The sign is used to mark buildings, auditoriums, companies and factories to indicate the spaces intended for exit or evacuation, in this case, doors to be operated with a bar
The poster is made with a layer of photoluminescent pigment (after absorbing light, the product emits it in the dark, so it does not need any electrical source and the product can be charged an indefinite number of times).
Theevacuation safety signsThey are used to indicate and guide people to emergency exits in the event of an event or situation that requires evacuation. These signs are essential to ensure safety and facilitate the quick and orderly evacuation of a building, auditorium, company or factory.
PRODUCT IDENTIFICATION
According to UNE 23035/4 standard:
- Name or brand of the manufacturer
- Manufacturing date
- Denomination (class A or class B as appropriate)
According to RIPCI 513:
- Name or brand of the manufacturer
MINIMUM LUMINESCENCE VALUES AFTER SALT CHAMBER
All NMZ signage is subjected to different internal and external light response tests that guarantee compliance with the light intensity values contemplated in the UNE 23035 standard.
CLASS A:
Time | Values from UNE 23035-4 (2003) CLASS A |
ValueSekureco CLASS A |
---|---|---|
Luminescence 10 minutes | 210 mcd/m2 | 225 mcd/m2 |
Luminescence 60 minutes | 29 mcd/m2 | 30 mcd/m2 |
Dimming time: | 3,000 minutes | 3,100 minutes |
CLASS B:
Time | Values from UNE 23035-4 (2003) CLASS A |
ValueSekureco CLASS A |
---|---|---|
Luminescence 10 minutes | 40 mcd/m2 | 50 mcd/m2 |
Luminescence 60 minutes | 5,6 mcd/m2 | 6,1 mcd/m2 |
Dimming time: | 800 minutes | 900 minutes |
CHARACTERISTICS
PVC SUPPORT MATERIALS
According to UNE 53127:
- White PVC 1 mm for class A and transparent PVC 0,7 mm for class B
- White lacquered aluminum 0.6 mm thick.
- Stability with Ta < 55o.
- Negligible water absorption (0.04 ± 0.01)%.
- Auto-extinguible.
- Not containing appreciable amounts of lead and phosphorus (less than 0,01%)
- Not toxic.
PICTOGRAMS
According to regulations:
- JOINS EN ISO 7010
- OTHER
TEXTS
- According to UNE 23033/1
PHOTOLUMINESCENT PRODUCT
- Composed of pigments.
- Unlimited photoluminescent charge and discharge cycles
COLOR
Tones according to standard:
- JOINS EN ISO 7010
- OTHER
- High adhesion and strength ink.
- It allows great flexibility in the final product.
- It's not self-igniting. Not toxic
FINAL THICKNESS
A class
- PVC 1.2 m/m (±10%).
- Aluminium 0,8 m/m (± 10%) or more
Clase B
- PVC 0,8 m/m (± 10%) or more.
- ALUMINUM 0.7 m/m (±10%).
REFERENCE
- Printed on the sign
DIMENSIONS
- According to UNE 23033/1
PERCENTAGE OF COLOUR
- According to UNE 23033-1 standard
MAXIMUM VIEWING DISTANCE
- Printed on the sign.
To calculate the necessary dimensions of a signal up to a maximum distance of 50 m, the formula shall be applied:
S≥ L2 /2000
“S” represents the area of the signal in square meters, and “L” the distance in meters from which the signal can be perceived.
MEASURES
Manufacture from materials of any heading
210X148 mm
297X210 mm
420X297 mm
NORMATIVE
- UNE 23034/1998 (evacuation) - fire safety. This is a security signal. Evacuation routes.
- UNE 23035-1/2003 - Safety against fire. Light-emitting signalling-
- UNE 23035-4/2003 - NMZ signals regularly pass radioactivity tests to ensure that the signalling element does not emit in accordance with the UNE standard. 23035 to 4.
- UNE 53127/2002 - Cellular plastics. Determination of the combustion characteristics of specimens in a horizontal position subjected to a small flame.
- UNE EN ISO 7010: 2012 - Graphic symbols. Colors and safety signs. Registered safety signs (ISO 7010:2011) (Ratified by AENOR in September 2012.)
- RD 314/2006 (CTE - Technical Building Code)
- RIPCI 2017 (Extinction) - Fire Protection Installations Regulations.
- NMZ signs are manufactured with a UNE-EN ISO 9001 certified quality management system
STORAGE, CLEANING AND PRESERVATION
The working temperature should not be higher than 45º C. Higher temperatures can deform the support material.
The optimal storage temperature will be between 15º C and 25º C; and with a humidity of 10/50%.
Cleaning methods; avoid applying abrasive products. It is recommended to clean them with water and neutral detergents.
The technical building code – Basic fire safety document requires that photoluminescent signage must comply with the UNE 23035 standard.
In order to preserve the functionality for which the signage systems have been designed, SEKURECO recommends keeping the signs free of dust, dirt or any debris or object that prevents their visibility and identification.
For cleaning, it is advisable to preferably use soapy solutions, avoiding the use of solvents or abrasive products that could damage the surface of the sign
Photoluminescent signals shall be so placed that they receive energy from a natural or artificial light source to ensure their correct operation.
In accordance with RD 513/2017 (TABLA III), luminous signalling systems shall be subject to an annual inspection/revision to be carried out by specialised personnel of the manufacturer, a maintenance company or the user or owner of the installation.
Once the useful life of the signals that make up the signaling system has expired, the inspection of said elements will be carried out following the instructions contained in RD 513/2017 and UNE 23035-2
SIGNAL INSTALLATION
Check out our blog to learn how to install a sign or poster:https://www.sekureco.eu/blog/76_consejos-de-instalacion-de-senales-de-seguridad.html
The recommended INSTALLATION HEIGHT ranges between 2 and 2.50 meters, always maintaining a separation distance of 0.30 meters from the ceiling.
Photoluminescent signs must be located so that they receive energy from a natural or artificial light source to ensure their correct operation.
The FIXING of the signaling element must be carried out on a firm surface free of dirt.
The sign may be secured using MECHANICAL ELEMENTS (screws, rivets, etc...) or ADHESIVES (assembly adhesive, glues, silicones...) carefully, avoiding soiling the visible surface or deforming it.
EVACUATION signage must be installed in such a way that an evacuation can be initiated from any point susceptible to occupation of the premises, so it is recommended to install directional signs on all routes, intersections, stairs, etc. that serve as a route.
The DOOR signage will be placed on the door lintel with the appropriate label (“EXIT”, “EMERGENCY EXIT”, NO EXIT”, …).
The signaling of MEANS OF PROTECTION against fire, rescue and/or aid will be carried out on the same elements to be signaled whenever possible.
APPLICATIONS
- Commercial and office buildings
- Hospitals and healthcare centers
- Schools and universities
- Airports and transportation stations
- Hotels
- Malls
- Industrial facilities and factories
- Theaters, cinemas and entertainment venues
- Restaurants and food establishments.
ABOUT COFAN
It is a company that has more than 15 years of experience in the hardware sector, industrial supply, and in the manufacture of safety footwear and other body protection equipment.
heading
Ficha Técnica Señal Salida de emergencia Presione la Barra para Abrir COFAN skrc download
Declaración de Conformidad El ensayo se realiza según el procedimiento PTICC/65 download
Declaración de Conformidad El ensayo se realiza según el procedimiento PTICC/65 download
@CUSTOMER_NAME@
@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@@COMMENT_TITLE@
@COMMENT_COMMENT@