€3.79 (no TAX)
Luminescent pictogram sign Exit Right Stair "Down" COFAN
Luminescent evacuation signal with only pictogram Exit Right Stair (up) COFAN. The pictogram indicates the arrow pointing right in white color.
The sign is made of luminescent PVC. Available in various sizes to choose from.
REPORT OF LUMINESCENCE TEST No. C/120257
€3.79 (no TAX)
Evacuation sign indicating Emergency exit staircase right down from the COFAN pictogram. It is a high-quality emergency sign that is easy to install. The sign is used to signal buildings, auditoriums, companies, and factories to indicate spaces designated for exit or evacuation. The direction of the sign indicates the right side.
The sign is made with a photoluminescent pigment layer (after absorbing light, the product emits it in the dark, so it does not require any electrical source and can be charged an indefinite number of times).
Evacuation safety signs are used to indicate and guide people to emergency exits in case of an event or situation that requires evacuation. These signs are essential to ensure safety and facilitate the quick and orderly evacuation of a building, auditorium, company, or factory.
PRODUCT IDENTIFICATION
According to UNE 23035/4:
- Name or brand of the manufacturer
- Date of manufacture
- Denomination (class A or class B as applicable)
According to RIPCI 513:
- Name or brand of the manufacturer
MINIMUM LUMINESCENCE VALUES AFTER SALINE CAMERA
All NMZ signage undergoes various internal and external light response tests that ensure compliance with the light intensity values outlined in UNE 23035.
CLASS A:
| Time | Values of UNE 23035-4 (2003) CLASS A |
Values Sekureco CLASS A |
|---|---|---|
| Luminescence 10 minutes | 210 mcd/m2 | 225 mcd/m2 |
| Luminescence 60 minutes | 29 mcd/m2 | 30 mcd/m2 |
| Fading time: | 3,000 minutes | 3,100 minutes |
CLASS B:
| Time | Values of UNE 23035-4 (2003) CLASS A |
Values Sekureco CLASS A |
|---|---|---|
| Luminescence 10 minutes | 40 mcd/m2 | 50 mcd/m2 |
| Luminescence 60 minutes | 5.6 mcd/m2 | 6.1 mcd/m2 |
| Fading time: | 800 minutes | 900 minutes |
CHARACTERISTICS
PVC SUPPORT MATERIALS
According to UNE 53127:
- White PVC 1mm for class A and transparent PVC 0.7mm for class B
- White lacquered aluminum with a thickness of 0.6mm.
- Stability with Tª < 55º.
- Negligible water absorption (0.04 ± 0.01)%.
- Self-extinguishing.
- No appreciable lead and phosphorus content (less than 0.01%)
- Non-toxic.
PICTOGRAMS
According to standards:
- UNE EN ISO 7010
- UNE 23033/1
TEXTS
- According to UNE 23033/1
PHOTOLUMINESCENT PRODUCT
- Made from pigments.
- Unlimited photoluminescent charge and discharge cycles
COLOR
Shades according to standard:
- UNE EN ISO 7010
- UNE 23033/1
- High adhesion and resistance ink.
- Allows for great flexibility in the final product.
- Non-flammable. Non-toxic
FINAL THICKNESS
Class A
- PVC 1.2 m/m (±10%).
- ALUMINUM 0.8 m/m (±10%).
Class B
- PVC 0.8 m/m (±10%).
- ALUMINUM 0.7 m/m (±10%).
REFERENCE
- Printed on the sign
DIMENSIONS
- According to UNE 23033/1
COLOR PERCENTAGES
- According to UNE 23033-1
MAXIMUM VIEWING DISTANCE
- Printed on the sign.
To calculate the necessary dimensions of a sign, the following formula will be applied, up to a maximum distance of 50 m:
S≥ L2 /2000
“S” represents the surface area of the sign in square meters, and “L” the distance in meters from which the sign can be perceived.
MEASURES
148X105 mm
210X148 mm
297X210 mm
420X297 mm
REGULATIONS
- UNE 23033/1:2019 (Extinction) - Fire safety. Signage
- UNE 23033/2:2019 (Installations) - Fire safety. Safety signage. Part 2: Signage and identification of fire protection installations.
- UNE 23034/1998 (Evacuation) - Fire safety. Safety Signage. Evacuation routes.
- UNE 23035-1/2003 - Fire safety. Photoluminescent signage-
- UNE 23035-4/2003 - NMZ signs periodically exceed radioactivity tests that guarantee no emission of the signaling element in compliance with UNE standard 23035-4.
- UNE 53127/2002 - Cellular plastics. Determination of combustion characteristics of specimens in a horizontal position subjected to a small flame.
- UNE EN ISO 7010: 2012 - Graphical symbols. Colors and safety signals. Registered safety signs (ISO 7010:2011) (Ratified by AENOR in September 2012.)
- RD 314/2006 (CTE - Technical Building Code)
- RIPCI 2017 (Extinction) - Regulation of Fire Protection Installations.
- NMZ signs are manufactured with a certified quality management system UNE-EN ISO 9001
STORAGE, CLEANING, AND CONSERVATION
The working temperature should not exceed 45º C. Higher temperatures may deform the support material.
The optimal storage temperature will be between 15º C and 25º C; and with a humidity of 10/50%.
Cleaning methods; avoid applying abrasive products. It is recommended to clean them with water and neutral detergents.
The technical building code - Basic document on fire safety requires that photoluminescent signage must comply with UNE 23035.
In order to maintain the functionality for which the signaling systems have been conceived, SEKURECO recommends keeping the signs free of dust, dirt, or any residue or object that hinders their visibility and identification.
For cleaning, it is advisable to use soapy solutions preferably, avoiding the use of solvents or abrasive products that may deteriorate the surface of the sign.
Photoluminescent signs should be positioned in such a way that they receive energy from a natural or artificial light source to ensure their proper functioning.
According to RD 513/2017 (TABLE III), luminous signaling systems must undergo an annual inspection/review carried out by specialized personnel from the manufacturer, a maintenance company, or by the user or owner personnel of the installation.
Once the useful life period of the signs that make up the signaling system has elapsed, the inspection of these elements will be carried out following the indications collected in RD 513/2017 and UNE 23035-2
SIGN INSTALLATION
Check our blog to learn how to install a sign or poster: https://www.sekureco.eu/blog/76_consejos-de-instalacion-de-senales-de-seguridad.html
The RECOMMENDED INSTALLATION HEIGHT ranges from 2 to 2.50 meters, always maintaining a separation distance of 0.30 meters from the ceiling.
Photoluminescent signs should be positioned in such a way that they receive energy from a natural or artificial light source to ensure their proper functioning.
The FIXING of the signaling element must be done on a firm surface free of dirt.
The sign can be secured using MECHANICAL ELEMENTS (screws, rivets, etc...) or ADHESIVES (mounting adhesive, glues, silicones…) carefully, avoiding soiling the visible surface or deforming it.
The EVACUATION signage should be installed in such a way that from any point likely to be occupied in the premises, an evacuation can be initiated, so it is recommended to install directional signs at all routes, intersections, stairs, etc. that serve as a path.
Signage on DOORS will be placed above the lintel with the appropriate label (“EXIT”, “EMERGENCY EXIT”, “NO EXIT”, …).
Signage for FIRE protection, rescue, and/or assistance will be carried out on the same elements to be signaled whenever possible.
APPLICATIONS
- Commercial and office buildings
- Hospitals and medical care centers
- Schools and universities
- Airports and transport stations
- Hotels
- Shopping centers
- Industrial facilities and factories
- Theaters, cinemas, and entertainment venues
- Restaurants and food establishments.
SOBRE COFAN
Es una empresa que cuenta con más de 15 años de experiencia en el sector de la ferretería, el suministro industrial, y en la fabricación de calzado de seguridad y demás equipos de protección corporal. La marca cuenta 28.000 referencias y muchos servicios especializados para mejorar la productividad y la rentabilidad de los negocios y hogares.