€6.57 (no TAX)
Sign in Catalan Punt of text and pictogram (Cofan)
Sign in Catalan Punt of text and pictogram (Cofan)
Measures: 297x210 and 420x297 mm
€6.24 (no TAX)
Evacuation sign indicating in Catalan that Punt of gathered Cofan, text and pictogram. High quality emergency signal and easy installation. The poster is used to sign up buildings, auditoriums, companies and factories to indicate the spaces intended for output or evacuation. The direction of the poster indicates the right side
The poster is made with a photoluminescent pigment layer, (after absorbing light, the product emits it in the dark, so it does not need any electrical source and the product can be charged an indefinite number of times).
Product identification
According to Norma UNE 23035/4:
- Name or brand of the manufacturer
- Manufacture date
- Denomination (Class A or Class B as appropriate)
According to Ripci 513:
- Name or brand of the manufacturer
Minimum values of luminescence after saline
All NMZ signaling is subjected to different internal and external trials of light response that guarantee compliance with the luminous intensity values referred to in the UNE 23035 standard.
Class A:
| Weather | VALUES OF UNE 23035-4 (2003) Class |
ValuesSekureco Class |
|---|---|---|
| Luminescence 10 minutes | 210 MCD / M2 | 225 MCD / M2 |
| Luminescence 60 minutes | 29 MCD / M2 | 30 MCD / M2 |
| Attenuation time: | 3,000 minutes | 3,100 minutes |
Class B:
| Weather | VALUES OF UNE 23035-4 (2003) Class |
ValuesSekureco Class |
|---|---|---|
| Luminescence 10 minutes | 40 MCD / M2 | 50 MCD / M2 |
| Luminescence 60 minutes | 5.6 MCD / M2 | 6.1 MCD / M2 |
| Attenuation time: | 800 minutes | 900 minutes |
Features
Materials Support PVC
According to NORMA UNE 53127:
- 1mm white PVC for class A and transparent PVC 0.7mm for class B
- Blank lacquered aluminum of 0.6mm thick.
- Stability with Tª <55º.
- Absorption of despicable water (0.04 ± 0.01)%.
- Self-extinguible.
- No content of appreciable lead and phosphorus (less than 0.01%)
- Non-toxic.
PICTOGRAMS
According to standards:
- UNE EN ISO 7010
- UNE 23033/1
TEXTS
- According to Norma UNE 23033/1
Photoluminescent product
- Compound based on pigments.
- Unlimited cargo and unloading photo-luminescent cycles
COLOR
Tones according to rule:
- UNE EN ISO 7010
- UNE 23033/1
- Ink of great adhesion and resistance.
- It allows great flexibility in the final product.
- Not self-flammable. Non-toxic
Final thickness
Class
- PVC 1.2 m / m (± 10%).
- 0.8 m / m aluminum (± 10%)
Class b
- PVC 0.8 m / m (± 10%).
- Aluminum 0.7 m / m (± 10%).
REFERENCE
- Printed on the signal
DIMENSIONS
- According to Norma UNE 23033/1
Color percentages
- According to Norma UNE 23033-1
Maximum view
- Printed on the signal.
To calculate the necessary dimensions of a signal, the formula is applied until a maximum distance of 50 m, the formula:
S≥ L2 / 2000
"S" represents the surface of the signal in square meters, and "L" distance in meters from the Quese can perceive the signal.
MEASURES
297x210 mm
420x297 mm
REGULATIONS
- UNE 23033/1: 2019 (Extinction) - Fire safety. Signaling
- UNE 23033/2: 2019 (Facilities) - Fire safety. Safety signage. Part 2: Signaling and identification of fire protection facilities.
- UNE 23034/1998 (Evacuation) - Fire safety. Safety signage. Evacuation routes.
- UNE 23035-1 / 2003 - Fire safety. Photoluminescent signage-
- UNE 23035-4 / 2003 - NMZ signals periodically outweigh radioactivity assays that guarantee the non-emission of the signaling element in compliance with the UNE standard. 23035-4.
- UNE 53127/2002 - Cell plastics. Determination of the combustion characteristics of specimens in horizontal position subjected to a small flame.
- UNE EN ISO 7010: 2012 - Graphic Symbols. Colors and safety signs. Registered Safety Signs (ISO 7010: 2011) (ratified by Aenor in September 2012.)
- RD 314/2006 (CTE - EDIFICATION TECNICAL CODE)
- Ripci 2017 (extinction) - Regulation of fire protection facilities.
- NMZ signals are manufactured with certified quality management system UNE-EN ISO 9001
Storage, cleaning and conservation
The working temperature should not be greater than 45º C. Higher temperatures may deform the support material.
The optimum storage temperature will be between 15º C and 25º C; and with a humidity of 10/50%.
Cleaning methods; Avoid applying abrasive products. It is recommended to clean them with water and neutral detergents.
The building technical code - Basic fire safety document requires that the photoluminescent signaling must comply with the UNE 23035 standard.
In order to preserve the functionality for which signaling systems have been conceived, Sekureco recommends maintaining free dust, dirt or any remaining or object signals that avoid visibility and identification of them.
For cleaning, it is advisable to use soapy solutions preferably, avoiding the use of solvents or abrasive products that may deteriorate the surface of the signal
Photoluminescent signals should be located in such a way that they receive the energy of a natural or artificial light source to ensure its proper functioning.
According to RD 513/2017 (Table III), luminescent signaling systems should undergo an annual inspection / review that will be carried out by specialized personnel from the manufacturer, from a maintenance company, or by the user staff or holder of The installation.
Once the lifespan of the signaling system is elapsed, the inspection of said elements will be carried out following the indications collected in RD 513/2017 and UNE 23035-2
Signal installation
Check our blog to know how to install a signal or poster:https://www.sekureco.eu/gb/blog/76_.html
The recommended installation height ranges between 2 and 2.50 meters, always maintaining a separation distance of 0.30 meters from the ceiling.
Photoluminescent signals should be located so that they receive the energy of a natural or artificial light source to ensure its proper functioning.
The fixation of the signaling element must be performed on a firm and free surface dirt.
The signal can be ensured by mechanical elements (screws, rivets, etc ...) or adhesives (assembly adhesive, tails, silicones ...) carefully, avoiding dirtying the view surface or the deformation thereof.
The evacuation signaling must be installed in such a way that from any point capable of occupation of the enclosure, an evacuation can be started, so it is recommended to install directional signals in all those routes, intersections, stairs, etc. That they serve as a tour.
Doors signaling will be placed on the lintel of it with the appropriate label ("exit", "emergency exit", without output ", ...).
The signaling of fire protection means, rescue and / or relief will be made on the same elements to signal whenever possible.
APPLICATIONS
Commercial and offices buildings.
Hotels and resorts.
Hospitals and medical centers.
Educational centers such as schools and universities.
Airports and train or bus stations.
Shopping centers and shops.
Cinemas, theaters and other entertainment places.
Sports facilities and stadiums.
Underground parking lots.
Boats and cruises.
On Cofan
It is a company that has more than 15 years of experience in the hardware sector, industrial supply, and in the manufacture of safety footwear and other body protection equipment.
SOBRE COFAN
Es una empresa que cuenta con más de 15 años de experiencia en el sector de la ferretería, el suministro industrial, y en la fabricación de calzado de seguridad y demás equipos de protección corporal. La marca cuenta 28.000 referencias y muchos servicios especializados para mejorar la productividad y la rentabilidad de los negocios y hogares.
@CUSTOMER_NAME@
@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@@COMMENT_TITLE@
@COMMENT_COMMENT@