Door signal Right evacuation Luminescent sekureco

Brand:

Door signal right evacuation Luminescent sekurec.
Measures: 210x210

Read moreShow less
€2.99
€2.99 (TAX incl.)
€2.47 (no TAX)

Order it before 23:59 and receive it between 11/05/2026 and 12/05/2026 with Agencia de transporte

Reference:
B10160

SECURE PAYMENT WITH

Pay in 3 interest-free installments with

(not applicable to companies)
more information

SHIPMENTS

from 3,99€ + VAT. Free from €150 +VAT

EXCHANGES AND RETURNS

Free up to 14 days after purchase, excluding personalized and made-to-order products

EXCHANGES AND RETURNS

WE HELP YOU

+34 876 43 01 24
info@sekureco.eu

You may also like
Description

Door signal right evacuation Luminescent sekurec. Class: B (PVC 0'7 mm). Measures: 210x210Emergency sign and high quality evacuation and easy installation. The poster is used to indicate what the evacuation doors are in buildings and enclosed spaces in case of emergency

Elaborated on PVC or aluminum plate with photoluminescent pigment layer, (after absorbing light, the product emits it in the dark, so it does not need any electrical source and the product can be charged an indefinite number of times).

Product identification

According to Norma UNE 23035/4:

  • Name or brand of the manufacturer
  • Manufacture date
  • Denomination (Class A or Class B as appropriate)

According to Ripci 513:

  • Name or brand of the manufacturer

Minimum values of luminescence after saline

All NMZ signaling is subjected to different internal and external trials of light response that guarantee compliance with the luminous intensity values referred to in the UNE 23035 standard.

Class A:

Weather VALUES OF UNE 23035-4 (2003)
Class
ValuesSekureco
Class
Luminescence 10 minutes 210 MCD / M2 225 MCD / M2
Luminescence 60 minutes 29 MCD / M2 30 MCD / M2
Attenuation time: 3,000 minutes 3,100 minutes

Class B:

Weather VALUES OF UNE 23035-4 (2003)
Class
ValuesSekureco
Class
Luminescence 10 minutes 40 MCD / M2 50 MCD / M2
Luminescence 60 minutes 5.6 MCD / M2 6.1 MCD / M2
Attenuation time: 800 minutes 900 minutes

Features

Materials Support PVC

According to NORMA UNE 53127:

  • 1mm white PVC for class A and transparent PVC 0.7mm for class B
  • Blank lacquered aluminum of 0.6mm thick.
  • Stability with Tª <55º.
  • Absorption of despicable water (0.04 ± 0.01)%.
  • Self-extinguible.
  • No content of appreciable lead and phosphorus (less than 0.01%)
  • Non-toxic.

PICTOGRAMS

According to standards:

  • UNE EN ISO 7010
  • UNE 23033/1

TEXTS

  • According to Norma UNE 23033/1

Photoluminescent product

  • Compound based on pigments.
  • Unlimited cargo and unloading photo-luminescent cycles

COLOR

Tones according to rule:

  • UNE EN ISO 7010
  • UNE 23033/1
  • Ink of great adhesion and resistance.
  • It allows great flexibility in the final product.
  • Not self-flammable. Non-toxic

Final thickness

Class

  • PVC 1.2 m / m (± 10%).
  • 0.8 m / m aluminum (± 10%)

Class b

  • PVC 0.8 m / m (± 10%).
  • Aluminum 0.7 m / m (± 10%).

REFERENCE

  • Printed on the signal

DIMENSIONS

  • According to Norma UNE 23033/1

Color percentages

  • According to Norma UNE 23033-1

Maximum view

  • Printed on the signal.

To calculate the necessary dimensions of a signal, the formula is applied until a maximum distance of 50 m, the formula:

S≥ L2 / 2000

"S" represents the surface of the signal in square meters, and "L" distance in meters from the Quese can perceive the signal.

MEASURES

Class B (PVC 0'7 mm)

  • B10160 .............. 210x210

REGULATIONS

- UNE 23033/1: 2019 (Extinction) - Fire safety. Signaling

- UNE 23033/2: 2019 (Facilities) - Fire safety. Safety signage. Part 2: Signaling and identification of fire protection facilities.

- UNE 23034/1998 (Evacuation) - Fire safety. Safety signage. Evacuation routes.

- UNE 23035-1 / 2003 - Fire safety. Photoluminescent signage-

- UNE 23035-4 / 2003 - NMZ signals periodically outweigh radioactivity assays that guarantee the non-emission of the signaling element in compliance with the UNE standard. 23035-4.

- UNE 53127/2002 - Cell plastics. Determination of the combustion characteristics of specimens in horizontal position subjected to a small flame.

- UNE EN ISO 7010: 2012 - Graphic Symbols. Colors and safety signs. Registered Safety Signs (ISO 7010: 2011) (ratified by Aenor in September 2012.)

- RD 314/2006 (CTE - EDIFICATION TECNICAL CODE)

- Ripci 2017 (extinction) - Regulation of fire protection facilities.

- NMZ signals are manufactured with certified quality management system UNE-EN ISO 9001

Storage, cleaning and conservation

The working temperature should not be greater than 45º C. Higher temperatures may deform the support material.

The optimum storage temperature will be between 15º C and 25º C; and with a humidity of 10/50%.

Cleaning methods; Avoid applying abrasive products. It is recommended to clean them with water and neutral detergents.

The building technical code - Basic fire safety document requires that the photoluminescent signaling must comply with the UNE 23035 standard.

In order to preserve the functionality for which signaling systems have been conceived, Sekureco recommends maintaining free dust, dirt or any remaining or object signals that avoid visibility and identification of them.

For cleaning, it is advisable to use soapy solutions preferably, avoiding the use of solvents or abrasive products that may deteriorate the surface of the signal

Photoluminescent signals should be located in such a way that they receive the energy of a natural or artificial light source to ensure its proper functioning.

According to RD 513/2017 (Table III), luminescent signaling systems should undergo an annual inspection / review that will be carried out by specialized personnel from the manufacturer, from a maintenance company, or by the user staff or holder of The installation.

Once the lifespan of the signaling system is elapsed, the inspection of said elements will be carried out following the indications collected in RD 513/2017 and UNE 23035-2

Signal installation

Check our blog to know how to install a signal or poster:https://www.sekureco.eu/gb/blog/76_.html

The recommended installation height ranges between 2 and 2.50 meters, always maintaining a separation distance of 0.30 meters from the ceiling.

Photoluminescent signals should be located so that they receive the energy of a natural or artificial light source to ensure its proper functioning.

The fixation of the signaling element must be performed on a firm and free surface dirt.

The signal can be ensured by mechanical elements (screws, rivets, etc ...) or adhesives (assembly adhesive, tails, silicones ...) carefully, avoiding dirtying the view surface or the deformation thereof.

The evacuation signaling must be installed in such a way that from any point capable of occupation of the enclosure, an evacuation can be started, so it is recommended to install directional signals in all those routes, intersections, stairs, etc. That they serve as a tour.

Doors signaling will be placed on the lintel of it with the appropriate label ("exit", "emergency exit", without output ", ...).

The signaling of fire protection means, rescue and / or relief will be made on the same elements to signal whenever possible.

About Sekureco

Experts in job security! We are a young company that arises in 2016 thanks to the passion of several technicians specialized in prevention and occupational safety and the lack of a company specialized in the sector. It offers one earnce of more than 10 thousand specialized products in labor protection, available to companies and individuals, the best brands and the most competitive prices on the market

Read moreShow less

SOBRE SEKURECO

Sekureco es una empresa que surge en 2016 gracias a la pasión de varios técnicos especializados en prevención y seguridad laboral y ante la falta de empresas realmente especializadas en protección laboral en el mercado.

Product Details
B10160
@COMMENT_AVATAR@

@CUSTOMER_NAME@

@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@
☆☆☆☆☆ ★★★★★ (@COMMENT_GRADE@)
@COMMENT_DATE@
@COMMENT_NO_APPROVE@

@COMMENT_TITLE@

@COMMENT_COMMENT@

@COMMENT_IMAGES@
@COMMENT_VIDEOS@
Write a comment
@COMMENT_AVATAR@

@CUSTOMER_NAME@

@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@
@COMMENT_DATE@
@COMMENT_NO_APPROVE@

@COMMENT_COMMENT@

Reply
@COMMENT_AVATAR@

@CUSTOMER_NAME@

@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@
@COMMENT_DATE@
@COMMENT_NO_APPROVE@

@COMMENT_COMMENT@

Reply

Menu