Fire extinguisher SOCK SIGNAL AND PICTOGRAM COFAN Available in several measures to adapt to the needs of your industry. This signal is used to indicate the existence of an extinguisher to be used in case of fires. With arrow pictogram in the direction below.
Thedistress posterIt is elaborated on luminescent plate, (after absorbing light, the product emits it in the dark, so it does not need any electrical source and the product can be charged an indefinite number of times).
This type of signals are installed in different types of industries as alert and safety measure, meanwhile, they comply with the function of keeping informative to users and workers of the emergency relief actions. In most industries, the security extinguisher is mandatory, as well as its correct signaling and instructions for use
It is common to find this sign, in schools, hospitals and factories, as well as in shopping centers, theaters and common space
Material:
Class B (PVC 0'7 mm)
Luminescent
Dimensions:
148 x 105 mm
210 x 148 mm
297 x 210 mm
420 x 297 mm
Product identification
According to Norma UNE 23035/4:
- Name or brand of the manufacturer
- Manufacture date
- Denomination (Class A or Class B as appropriate)
According to Ripci 513:
- Name or brand of the manufacturer
Minimum values of luminescence after saline
All NMZ signaling is subjected to different internal and external trials of light response that guarantee compliance with the luminous intensity values referred to in the UNE 23035 standard.
Class A:
| Weather | VALUES OF UNE 23035-4 (2003) Class |
ValuesSekureco Class |
|---|---|---|
| Luminescence 10 minutes | 210 MCD / M2 | 225 MCD / M2 |
| Luminescence 60 minutes | 29 MCD / M2 | 30 MCD / M2 |
| Attenuation time: | 3,000 minutes | 3,100 minutes |
Class B:
| Weather | VALUES OF UNE 23035-4 (2003) Class |
ValuesSekureco Class |
|---|---|---|
| Luminescence 10 minutes | 40 MCD / M2 | 50 MCD / M2 |
| Luminescence 60 minutes | 5.6 MCD / M2 | 6.1 MCD / M2 |
| Attenuation time: | 800 minutes | 900 minutes |
Features
Materials Support PVC
According to NORMA UNE 53127:
- 1mm white PVC for class A and transparent PVC 0.7mm for class B
- Blank lacquered aluminum of 0.6mm thick.
- Stability with Tª <55º.
- Absorption of despicable water (0.04 ± 0.01)%.
- Self-extinguible.
- No content of appreciable lead and phosphorus (less than 0.01%)
- Non-toxic.
PICTOGRAMS
According to standards:
- UNE EN ISO 7010
- UNE 23033/1
TEXTS
- According to Norma UNE 23033/1
Photoluminescent product
- Compound based on pigments.
- Unlimited cargo and unloading photo-luminescent cycles
COLOR
Tones according to rule:
- UNE EN ISO 7010
- UNE 23033/1
- Ink of great adhesion and resistance.
- It allows great flexibility in the final product.
- Not self-flammable. Non-toxic
Final thickness
Class
- PVC 1.2 m / m (± 10%).
- 0.8 m / m aluminum (± 10%)
Class b
- PVC 0.8 m / m (± 10%).
- Aluminum 0.7 m / m (± 10%).
REFERENCE
- Printed on the signal
DIMENSIONS
- According to Norma UNE 23033/1
Color percentages
- According to Norma UNE 23033-1
Maximum view
- Printed on the signal.
To calculate the necessary dimensions of a signal, the formula is applied until a maximum distance of 50 m, the formula:
S≥ L2 / 2000
"S" represents the surface of the signal in square meters, and "L" distance in meters from the Quese can perceive the signal.
MEASURES
Class B (PVC 0'7 mm)
148 x 105 mm
210 x 148 mm
297 x 210 mm
420 x 297 mm
APPLICATIONS
Public buildings
Government Offices
Schools
Hospitals
Factories
Shopping centers and others
REGULATIONS
The regulations connect 23035-4 December 2003, forces the signals to certain qualities of light intensity and resistance to the attenuation of the pigment. Both the inks, and the photoluminescent PVC used in the realization of our signals fully comply with said regulation. Since safety signage can contribute to saving lives, and is mandatory, use the best possible signaling. Recommendations for use: minimum sizes to be used depending on the meters.
Storage, cleaning and conservation
The working temperature should not be greater than 45º C. Higher temperatures may deform the support material.
The optimum storage temperature will be between 15º C and 25º C; and with a humidity of 10/50%.
Cleaning methods; Avoid applying abrasive products. It is recommended to clean them with water and neutral detergents.
The building technical code - Basic fire safety document requires that the photoluminescent signaling must comply with the UNE 23035 standard.
In order to preserve the functionality for which signaling systems have been conceived, Sekureco recommends maintaining free dust, dirt or any remaining or object signals that avoid visibility and identification of them.
For cleaning, it is advisable to use soapy solutions preferably, avoiding the use of solvents or abrasive products that may deteriorate the surface of the signal
Photoluminescent signals should be located in such a way that they receive the energy of a natural or artificial light source to ensure its proper functioning.
According to RD 513/2017 (Table III), luminescent signaling systems should undergo an annual inspection / review that will be carried out by specialized personnel from the manufacturer, from a maintenance company, or by the user staff or holder of The installation.
Once the lifespan of the signaling system is elapsed, the inspection of said elements will be carried out following the indications collected in RD 513/2017 and UNE 23035-2
Signal installation
Check our blog to know how to install a signal or poster:https://www.sekureco.eu/gb/blog/76_.html
The recommended installation height ranges between 2 and 2.50 meters, always maintaining a separation distance of 0.30 meters from the ceiling.
Photoluminescent signals should be located so that they receive the energy of a natural or artificial light source to ensure its proper functioning.
The fixation of the signaling element must be performed on a firm and free surface dirt.
The signal can be ensured by mechanical elements (screws, rivets, etc ...) or adhesives (assembly adhesive, tails, silicones ...) carefully, avoiding dirtying the view surface or the deformation thereof.
The evacuation signaling must be installed in such a way that from any point capable of occupation of the enclosure, an evacuation can be started, so it is recommended to install directional signals in all those routes, intersections, stairs, etc. That they serve as a tour.
Doors signaling will be placed on the lintel of it with the appropriate label ("exit", "emergency exit", without output ", ...).
The signaling of fire protection means, rescue and / or relief will be made on the same elements to signal whenever possible.
On Cofan
It is a company that has more than 15 years of experience in the hardware sector, industrial supply, and in the manufacture of safety footwear and other body protection equipment.
SOBRE COFAN
Es una empresa que cuenta con más de 15 años de experiencia en el sector de la ferretería, el suministro industrial, y en la fabricación de calzado de seguridad y demás equipos de protección corporal. La marca cuenta 28.000 referencias y muchos servicios especializados para mejorar la productividad y la rentabilidad de los negocios y hogares.
@CUSTOMER_NAME@
@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@@COMMENT_TITLE@
@COMMENT_COMMENT@