Right Evacuation Door Sign luminescent SEKURECO

Brand:

Right Evacuation Door Signal luminescent SEKURECO.
Dimensions: 210X210

Read moreShow less
€2.99
€2.99 (TAX incl.)
€2.47 (no TAX)

Order it before 23:59 and receive it between 05/06/2026 and 08/06/2026 with Agencia de transporte

Reference:
B10160

SECURE PAYMENT WITH

Pay in 3 interest-free installments with

(not applicable to companies)
more information

SHIPMENTS

from 3,99€ + VAT. Free from €150 +VAT

EXCHANGES AND RETURNS

Free up to 14 days after purchase, excluding personalized and made-to-order products

EXCHANGES AND RETURNS

WE HELP YOU

+34 876 43 01 24
info@sekureco.eu

You may also like
Description

Evacuation Door Signal Right luminescent SEKURECO. Class: B (PVC 0.7 mm). Dimensions: 210X210. High-quality emergency and evacuation sign that is easy to install. The sign is used to indicate which are the evacuation doors in buildings and enclosed spaces in case of emergency.

Made on a PVC or aluminum sheet with a photoluminescent pigment layer (after absorbing light, the product emits it in the dark, so it does not require any electrical source and can be charged an indefinite number of times).

PRODUCT IDENTIFICATION

According to UNE 23035/4:

  • Manufacturer's name or brand
  • Manufacturing date
  • Denomination (class A or class B as applicable)

According to RIPCI 513:

  • Manufacturer's name or brand

MINIMUM LUMINESCENCE VALUES AFTER SALT CHAMBER

All NMZ signage undergoes various internal and external light response tests that guarantee compliance with the light intensity values outlined in the UNE 23035 standard.

CLASS A:

Time UNE 23035-4 (2003) Values
CLASS A
Values Sekureco
CLASS A
10 minutes luminescence 210 mcd/m2 225 mcd/m2
60 minutes luminescence 29 mcd/m2 30 mcd/m2
Decay time: 3,000 minutes 3,100 minutes

CLASS B:

Time UNE 23035-4 (2003) Values
CLASS A
Values Sekureco
CLASS A
10 minutes luminescence 40 mcd/m2 50 mcd/m2
60 minutes luminescence 5.6 mcd/m2 6.1 mcd/m2
Decay time: 800 minutes 900 minutes

FEATURES

PVC SUPPORT MATERIALS

According to UNE 53127:

  • White PVC 1mm for class A and transparent PVC 0.7mm for class B
  • White lacquered aluminum 0.6mm thick.
  • Stability with Tª < 55º.
  • Negligible water absorption (0.04 ± 0.01)%.
  • Self-extinguishing.
  • No appreciable lead and phosphorus content (less than 0.01%)
  • Non-toxic.

PICTOGRAMS

According to standards:

  • UNE EN ISO 7010
  • UNE 23033/1

TEXTS

  • According to UNE 23033/1

PHOTOLUMINESCENT PRODUCT

  • Made from pigments.
  • Unlimited photoluminescent charge and discharge cycles

COLOR

Shades according to standard:

  • UNE EN ISO 7010
  • UNE 23033/1
  • High adhesion and resistance ink.
  • Allows great flexibility in the final product.
  • Non-flammable. Non-toxic

FINAL THICKNESS

Class A

  • PVC 1.2 mm (±10%).
  • ALUMINUM 0.8 mm (±10%).

Class B

  • PVC 0.8 mm (±10%).
  • ALUMINUM 0.7 mm (±10%).

REFERENCE

  • Printed on the sign

DIMENSIONS

  • According to UNE 23033/1

COLOR PERCENTAGES

  • According to UNE 23033-1

MAXIMUM VIEWING DISTANCE

  • Printed on the sign.

To calculate the necessary dimensions of a sign, the following formula will be applied, up to a maximum distance of 50 m:

S≥ L2 /2000

“S” represents the surface area of the sign in square meters, and “L” the distance in meters from which the sign can be perceived.

MEASURES

CLASS B (PVC 0.7 mm)

  • B10160..............210X210

REGULATIONS

- UNE 23033/1:2019 (Extinction) - Fire safety. Signage

- UNE 23033/2:2019 (Installations) - Fire safety. Safety signage. Part 2: Signage and identification of fire protection installations.

- UNE 23034/1998 (Evacuation) - Fire safety. Safety Signage. Evacuation routes.

- UNE 23035-1/2003 - Fire safety. Photoluminescent signage-

- UNE 23035-4/2003 - NMZ signs periodically exceed radioactivity tests that guarantee the non-emission of the signaling element in compliance with UNE standard 23035-4.

- UNE 53127/2002 - Cellular plastics. Determination of combustion characteristics of specimens in horizontal position subjected to a small flame.

- UNE EN ISO 7010: 2012 - Graphical symbols. Colors and safety signals. Registered safety signs (ISO 7010:2011) (Ratified by AENOR in September 2012.)

- RD 314/2006 (CTE - Technical Building Code)

- RIPCI 2017 (Extinction) - Regulation of Fire Protection Installations.

- NMZ signs are manufactured with a certified quality management system UNE-EN ISO 9001

STORAGE, CLEANING, AND CONSERVATION

The working temperature should not exceed 45º C. Higher temperatures may deform the support material.

The optimal storage temperature is between 15º C and 25º C; with a humidity of 10/50%.

Cleaning methods; avoid using abrasive products. It is recommended to clean them with water and neutral detergents.

The technical building code – Basic document on fire safety requires that photoluminescent signage must comply with UNE 23035 standard.

In order to preserve the functionality for which the signaling systems have been conceived, SEKURECO recommends keeping the signs free of dust, dirt, or any residue or object that prevents visibility and identification of them.

For cleaning, it is advisable to use soapy solutions preferably, avoiding the use of solvents or abrasive products that may deteriorate the surface of the sign.

Photoluminescent signs should be positioned in such a way that they receive energy from a natural or artificial light source to ensure their proper functioning.

According to RD 513/2017 (TABLE III), luminescent signaling systems must undergo an annual inspection/review conducted by specialized personnel from the manufacturer, a maintenance company, or by the user or owner personnel of the installation.

Once the useful life period of the signs that make up the signaling system has elapsed, the inspection of these elements will be carried out following the indications collected in RD 513/2017 and UNE 23035-2

SIGN INSTALLATION

Check our blog to learn how to install a sign or poster: https://www.sekureco.eu/blog/76_consejos-de-instalacion-de-senales-de-seguridad.html

The RECOMMENDED INSTALLATION HEIGHT ranges between 2 and 2.50 meters, always maintaining a distance of 0.30 meters from the ceiling.

Photoluminescent signs should be positioned to receive energy from a natural or artificial light source to ensure their proper functioning.

The FIXING of the signaling element must be done on a firm and clean surface.

The sign can be secured using MECHANICAL ELEMENTS (screws, rivets, etc...) or ADHESIVES (mounting adhesive, glues, silicones…) carefully, avoiding soiling the visible surface or deforming it.

The EVACUATION signage should be installed in such a way that from any point likely to be occupied in the premises, an evacuation can be initiated, so it is recommended to install directional signs on all routes, intersections, stairs, etc. that serve as a pathway.

The signage on DOORS will be placed above the lintel with the appropriate label (“EXIT”, “EMERGENCY EXIT”, “NO EXIT”, ...).

The signage for FIRE protection, rescue, and/or assistance will be carried out on the same elements to be signaled whenever possible.

Read moreShow less

SOBRE SEKURECO

Sekureco es una empresa que surge en 2016 gracias a la pasión de varios técnicos especializados en prevención y seguridad laboral y ante la falta de empresas realmente especializadas en protección laboral en el mercado.

Product Details
B10160
@COMMENT_AVATAR@

@CUSTOMER_NAME@

@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@
☆☆☆☆☆ ★★★★★ (@COMMENT_GRADE@)
@COMMENT_DATE@
@COMMENT_NO_APPROVE@

@COMMENT_TITLE@

@COMMENT_COMMENT@

@COMMENT_IMAGES@
@COMMENT_VIDEOS@
Write a comment
@COMMENT_AVATAR@

@CUSTOMER_NAME@

@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@
@COMMENT_DATE@
@COMMENT_NO_APPROVE@

@COMMENT_COMMENT@

Reply
@COMMENT_AVATAR@

@CUSTOMER_NAME@

@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@
@COMMENT_DATE@
@COMMENT_NO_APPROVE@

@COMMENT_COMMENT@

Reply

Menu